Retrotec Triple Fan Blower Door System Setup with DM-2 User Manual

Browse online or download User Manual for Safety Retrotec Triple Fan Blower Door System Setup with DM-2. Retrotec Triple Fan Blower Door System Setup with DM-2 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page 1 of 6
QG320 rev-2011-10-10
QuickGuide-Blower Door-QMG 3 Gauge
Read and experiment with each step
To perform automatic or multi-point tests*, refer to the FanTestic Software Manual and the DM-2 Operator’s Manual
*Tests for CGSB 149, LEED, ASTM E778, ASTM 1827, EN13829, and ATTMA TS-1 may require more elaborate steps and training. This guide is
intended only for familiarization with the controls.
For the latest Retrotec documentation, visit us at: http://www.retrotec.com/
1 Setup the DM-2s
1.1 Setup the DM-2s as needed for the required
testing standards
See: QuickGuide-DM2MkII
1.2 Ensure that rechargeable
batteries are fully charged
(may take eight hours or
more), or that spare
batteries are available for
each gauge.
2 Set up the building
2.1 Close the outside doors and windows.
2.2 Open all interior doors leading to conditioned
spaces.
2.3 Shut off HVAC (exhaust fans, dryers, A/C,
furnaces).
2.4 Turn gas hot water to pilot.
2.5 Place paper over any open ashes.
Close all windows
Gas valve to Pilot
Cover ashes with paper
Fans must be plugged into three
separate circuits!
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - 2 Set up the building

Page 1 of 6 QG320 rev-2011-10-10 QuickGuide-Blower Door-QMG 3 Gauge  Read and experiment with each step  To pe

Page 2 - Page 2 of 6

Page 2 of 6 3 Unpack the fan panels 3.1 Remove the 3-Fan panel from the case. 3.2 Stand the panel on its side, and unfold the sections. 3.3 Lock b

Page 3 - 12 Connect DM-2 #1 to Drive

Page 3 of 6 9 Seal any remaining gaps 9.1 Depending on the height of the doorway, a gap may be left open between the top of the panel and the door f

Page 4

Page 4 of 6 13 Connect the variable speed drives 13.1 Plug each drive into a 20 amp outlet (not GFCI), on an independent circuit, to avoid tripping t

Page 5

Page 5 of 6 20 Remove fan cover and set range 20.1 Remove the fan covers from all three fans. 20.2 All three fans should be open, with all range pla

Page 6 - 26 Securing the 6-Fan system

Page 6 of 6 25 Setting up a 6-Fan system 25.1 If additional airflow is required, six fans can be connected and controlled together. 25.2 Connect two

Comments to this Manuals

No comments