2000 Series , double wall fan as found in
Q46, Q56
120VAC
12 (1440W)
15.5A (1860W)
208VAC
6.2A (1290W)
7.6A (1580W)
2350 , double wall fan as found in Q46,
Q56
120VAC
10A (1200W)
23A (2760W)
208VAC
4.5A (936W)
10A (2080W)
1000 Wheel rim style, single layer
120VAC
12A (1440W)
23A (2760W)
208VAC
4.8A (998W)
11A (2288W)
DU200 Series DucTester
120VAC
2A (240W)
2.5A (300 W)
500 W
208VAC
N/A
N/A
DU200 w/2350 Fan Top
120VAC
2A (240W)
3A (360W)
208VAC
0.9A (187W)
1.2A (250W)
When selecting the generator, look for key words and phrases including:
“inverter output
“utility-grade AC power”
“suitable for sensitive electronics
Table 6: Portable generator AC power output types.
Type of AC Power Output
Comments/Expectation
Inverter
Best; Compatible
Recommended
AVR Automatic Voltage Regulation
Questionable; May not perform
Not Recommended
Brushless
Worse; May not perform
Not Recommended
CycloConverter
Worst; May not perform
Not Recommended
7.4 Recommended Generators
7.4.1. Honda Generator EU2000
(120V, 2000W, 67 lbs)
Works will all DucTester fan models.
Works with both 2200 and 2350 series fans.
The Honda EU2000 provides 2000 watts and 120V AC power. It is equipped with an
inverter, and is specially designed for sensitive electronic equipment. At 16.7 Amps, it
meets the needs of most Retrotec equipment, although it does fall below the
recommended minimum power output.